Technical Features
- Positive Tubular Plates: designed with a low selenium lead alloy to reduce water loss and increase intervals between watering (36 months when operated under
- float conditions).
- The tubular design prevents the loss of active material during operation, resulting in longer operating life.
- Negative Flat Plates: rugged pasted grid construction designed to have a service life consistent with the positive plates.
- Electrolyte: high purity sulfuric acid solution with 1.24 specific gravity at 77°F (± 0.01) when fully charged.
- Separators: made with a high porosity / low resistance material for high efficiency and low self discharge rates.
- Containers: made from an acid resistant transparent SAN material, designed for unsurpassed mechanical strength and easy cell status inspection.
- Covers: made of an opaque ABS material.
- Terminal posts: female threaded M10 terminal posts provide high conductivity, retain required torque values and allow for easy installation.
- Post seals: developed with a high integrity design to pre-vent electrolyte leakage and eliminate terminal corrosion.
- Vent Caps: effectively prevents acid spray from the cell when ‘gassing’ during boost charge. Caps are provided with a ceramic filter and bayonet lock, designed to prevent any errant spark or flame from entering the cell.
- Connectors: flexible cable design is fully insulated and is provided with an insulated screw which allows for easy meter probe access.
- Capacities: proven to exceed DIN standard nominal values.
- Shelf life: < 3% self-discharge per month at 77°F al-lows up to 6 months shelf life before boosting is required.
- Installation: designed for vertical orientation.